PV3300 TLV Series Low Frequency Split Phase Inverter Charger (AC:110/220V 1-6KW) PV3300 TLV Series Low Frequency Split Phase Inverter Charger (AC:110/220V 1-6KW) PV3300 TLV Series Low Frequency Split Phase Inverter Charger (AC:110/220V 1-6KW)

Low Frequency Split Phase Inverter Charger

PV3300 TLV Split Phase (AC:110/220V 1-6KW)

This split phase solar inverter PV3300 TLV series, capacity range from 1KW-6KW, DC 12V/24V/48V, it’s applicable to 110VAC/120VAC markets demands, which has AC output of single phase 110VAC/120V, split phase 220V/240V; In LCD display, you can set output voltage, frequency, charging voltage, charging current to design best use based on different loads applications; meanwhile, it has built-in MPPT solar charge controller 80A, you can take use of sunshine freely and save electricity bills.

Features:
  • Pure sine wave output
  • Friendly user interface; MFD (multi-function display)
  • 3 Steps charging
  • Overload and short-circuit protection
  • Set charging voltage/charging current.
  • Battery low voltage shutdown point can be set to 10/10.5/11/11.5V
  • Set utility priority/ Battery priority
  • Set utility input wide/narrow range
  • Inverter voltage can be set to 100/110/120; frequency can be set to 50/60Hz
  • Set utility charging on/off switch
  • Built-in 80A MPPT charger
  • Acid or Lithium Select
  • WiFi port (optional)
Where to Buy?

Overview

↓↓↓Installation Portfolio------------

MUSTENERGY
MODELPV33- 1012 TLVPV33- 1512 TLVPV33- 1524 TLVPV33- 2012 TLVPV33- 2024 TLVPV33- 3024 TLVPV33- 3048 TLVPV33- 4024 TLVPV33- 4048 TLVPV33- 5048 TLVPV33- 6048 TLV
Inverter Output
Rated power1KW1.5KW2KW3KW4KW5KW6KW
Power factor1
Wave formPure sine wave
Output voltage RMS100V / 110V / 120VAC (200V / 220V / 240VAC, L+L) ±10%
Output frequency50Hz or 60Hz (±0.3Hz)
Inverter efficiency (peak)>85%
Line mode efficiency>95%
Overload100%<Load<110% (alarm 5min then stop output ) / 110%<Load<125% (alarm 60s then stop output) / Load > 125% (alarm 10s then stop output )
Surge rating3000VA4500VA6000VA9000VA12000VA15000VA18000VA
Capable of starting electric motor1HP1HP1.5HP1.5HP2HP3HP
Battery
Battery voltage12VDC/24VDC24VDC/48VDC48VDC
Minimum start voltage(10V / 10.5V / 11V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low battery voltage cut off10V / 10.5V / 11V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low battery voltage alarm(10V / 10.5V / 11V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High battery voltage alarm(13.8-14.5V)+1V for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover(13.8-14.5V)+0.5V  for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
Save modeLoad ≤50±20W(120V)/100±20W(220V)
AC Input Mode
Input waveformPure sine wave
Nominal input voltage200Vac / 220Vac / 240Vac
Max input voltage270Vac MAX
Input frequency50Hz / 60Hz (auto sensing)
Efficiency (AC mode)>95% (load, full battery)
Transfer time AC to DC15ms(typical)
Solar Charger
Maximum PV Array Power1250W1250W2500W1250W2500W2500W5000W2500W5000W5000W5000W
Maximum PV Charge Current80A
DC Voltage12V / 24V24V / 48V24V / 48V
MPPT Range @ Operating Voltage16~95VDC @ 12V / 30~130VDC @ 24V30~130VDC @ 24V  / 60~130VDC @48V60~130VDC @48V
Maximum PV Array Open Circuit Voltage100±2Vdc / 145±2Vdc145±2Vdc145±2Vdc
Maximum Efficiency>98%
Standby Power Consumption<2W
Charge Mode
12V30A45A60A////
24V20A25A30A40A60A//
48V///20A30A35A40A
Min charge current 10A. Change by every 5A
Dimensions
Dimensions (W*H*D)277*196*466mm277*186*621mm
Ship Dimensions (W*H*D)376*306*592mm376*296*747mm
Net Weight (Solar CHG)(kg)17.217.721.820.725.225.538.936.53839
Shipping Weight (Solar CHG)(kg)2020.724.823.528.228.24340.739.240.2
Warranty1year