PV3000 MPK Series Low Frequency Off Grid Solar Inverter (1-6KW) PV3000 MPK Series Low Frequency Off Grid Solar Inverter (1-6KW) PV3000 MPK Series Low Frequency Off Grid Solar Inverter (1-6KW)

Low Frequency Off Grid Solar Inverter

PV3000 MPK Series (1-6KW)

PV3000 MPK series is a multi-function inverter ,combining functions of inverter and mppt solar charger controller, solar charger and battery charger to offer uninterruptible power support with portable size. The comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and selectable input voltage based on different applications.

Features:
  • Pure Sine Wave Output
  • Built-in MPPT solar charge controller 80A
  • Support Remote Control Box(optional)
  • LCD display ,easy to read how inverter operates on LCD screen
  • Compatible to generator
  • 5 -levels DIP switch ,offering customized performance
  • 9 – levels battery selector ,Enable to charge Gel , lead-acid battery
  • DC(Solar)/AC prority optional
  • 4 levels charge current adjustable
  • With RS232 communication port
  • With BTS & GTS , optimazing battery performance & start generator automatically
  • Power saver Switch , Enable to minimize standby consumption
Where to Buy?

Overview

Pure sine wave output

Perfectly driving inductive load current


Smart Battery Chargers

Smart battery charger design for optimized battery performance.


Remote control

Control with a wired remote control panel The remote control is particularly suitable when the power-source manager is installed behind a casing or in a place that prevents you from accessing the device. The remote control allows you to switch the power saving mode on/off easily. Please note that remote control panel is not optional, not included in inverter package.


LCD display, easy to read how inverter operates on LCD screen


Line Mode

When utility is the unit the battery from the utility,LCD indicate charge current.

In utility mode the unit provide output power from the utility, the indication and displays are following figures:


Battery Mode

In battery mode the unit will provide output power from battery or PV, LCD indicate battery capacity


Fault Mode

When inverter fault, the indication and displays are as following figures:

2 ——- fan jam / overload
3/6/7 ——- output short circuit
4 ——- over temperature
8/9 ——- battery over voltage.


PRODUCT DETAILS


INVERTER SYSTEM CONNECTION


APPLICABLE PLACE


ACTUAL CASE


Specification

MODELPV30-1KWMPKPV30-1.5KWMPKPV30-2KWMPKPV30-3KWMPKPV30-4KWMPKPV30-5KWMPKPV30-6KWMPK
Nominal Battery System Voltage12VDC24VDC12VDC24VDC12VDC24VDC12VDC24VDC24VDC48VDC24VDC48VDC24VDC48VDC
INVERTER OUTPUT
Rated Power1KW1.5KW2KW3KW4KW5KW6KW
Surge Rating (20ms)3KW4.5KW6KW9KW12KW15KW18KW
Capable Of Staring Electric Motor1HP1HP1HP2HP2HP3HP3HP
WaveformPure sine wave / same as input (bypass mode)
Nominal Output Voltage RMS110V / 120V / 220V / 230V / 240VAC (±10% RMS)110V/120V220V/230V/240V220V / 230V /240VAC
Output Frequency50Hz/60Hz ±0.3Hz
Inverter Efficiency (Peak)>88%
Line Mode Efficiency>95%
Power Factor1.0
Typical Transfer Time10(max)
AC INPUT
Voltage230VAC
Selectable Voltage Range96~132VAC / 155~280VAC (For personal computer)
Frequency Range50Hz/60Hz (Auto sensing) 40-80Hz
BATTERY
Minimum Start Voltage10.0VDC/10.5VDC for 12VDC mode (*2 for 24VDC)20.0VDC~21.0VDC / 40.0VDC~42.0VDC
Low Battery Alarm10.5VDC±0.3V for 12VDC mode (*2 for 24VDC)21.0 VDC±0.6V / 42.0VDC±1.2V
Low Battery Cutoff10.0VDC/±0.3V for 12VDC mode (*2 for 24VDC)20.0 VDC±0.6V / 40.0VDC±1.2V
High Voltage Alarm16.0VDC/±0.3V for 12VDC mode (*2 for 24VDC)32.0 VDC±0.6V / 64.0VDC±1.2V
High Battery Voltage Recover15.5VDC/±0.3V for 12VDC mode (*2 for 24VDC)31.0 VDC±0.6V / 62.0VDC±1.2V
Idie Consumption Search Mode<25W when power saver on<50W when power saver on
AC CHARGER
Output VoltageDepends on battery type
Charger AC Input Breaker Rating10A30A30A30A40A
Overcharge Protection S.D.15.7VDC for 12VDC mode (*2 for 24VDC)31.4VDC/62.8VDC
Maximum Charge Current35A20A45A25A65A35A75A45A65A35A70A40A75A50A
BYPASS& PROTECTION
Input Voltage WaveformSine wave (grid or generator)
Nominal Input Frequency50Hz or 60Hz
Overload Protection (SMPS Load)Circuit breaker
Output Short Circuit ProtectionCircuit breaker
Bypass Breaker Rating10A15A30A30A40A
Max Bypass Current30Amp40Amp
SOLAR CHARGER
Maximum PV Array Power1250W2500W1250W2500W1250W2500W1250W2500W2500W5000W2500W5000W2500W5000W
Maximum PV Charge Current80A80A
DC Voltage12V/24V auto work24V/48V auto work
MPPT Range @ Operating Voltage16~100VDC @ 12V/32~145VDC @ 24V32~145VDC @ 24V/64~145VDC @ 48V
Maximum PV Array Open Circuit Voltage145VDC
Maximum Efficiency>90%>98%
Standby Power Consumption<2W<2W
MECHANICAL SPECIFICATIONS
Dimensions (W*H*D)423*247*197597*247*197
Net Weight (Solar CHG) (kg)18.518.419.519.423.522.228.72741.339.450.448.851.849.1
Shipping Dimensions (W*H*D)570*355*300mm743*372*312mm
Shipping Weight (Solar CHG) (kg)21.521.422.422.525.825.631.229.644.742.85452.455.753.1
OTHER
Operation Temoerature Range0 ℃ to 40℃
Storage Temperature Range-15℃ to 60℃
Audible Noise60dB MAX
Loading (20GP/40GP/40HQ)460pcs / 920pcs / 1060pcs320pcs / 640pcs /750pcs