PV3000 LVHM Series Low Frequency Solar Inverter (AC:120V 1-6KW) PV3000 LVHM Series Low Frequency Solar Inverter (AC:120V 1-6KW) PV3000 LVHM Series Low Frequency Solar Inverter (AC:120V 1-6KW)

Low Frequency Solar Inverter

PV3000 LVHM Series (AC:120V 1-6KW)

PV3000 LVHM series is very economical pure sine wave solar inverter, AC voltage 110V/120V, AC charger inbuilt, from 20A to 60A; MPPT solar charger 80A inbuilt; Solar/AC priority is configurable, when setting solar priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current is not enough, it enables inverter to operate with all kinds of home appliances, widely selling to Latin America.

Features:
  • Pure sine wave output
  • 3 Steps charging
  • Overload and short-circuit protection
  • Set charging voltage/charging current.
  • Battery low voltage shutdown point can be set to 10/10.5/11V/11.5V
  • Power-save mode
  • Set utility priority/ Battery priority
  • Set utility input wide/narrow range
  • Inverter voltage can be set to 120V:110V/115V/120V
  • Inverter frequency can be set to 50/60Hz
  • Set utility charging on/off switch
  • 80A MPPT charger
  • Acid or Lithium Select
  • WiFi port (optional)
Where to Buy?

Overview

↓↓↓Installation Portfolio------------

MUSTENERGY
MODEL PV30-1KW LVHM PV30-1.5KW LVHM PV30-2KW LVHM PV30-3KW LVHM PV30-4KW LVHM PV30-5KW LVHM PV30-6KW LVHM
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC 48VDC 24VDC 48VDC 48VDC 48VDC
INVERTER OUTPUT
Rated Power 1 KW 1.5 KW 2 KW 3 KW 4 KW 5 KW 6 KW
Surge Rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
Capable Of Starting Electric Motor 1HP 1HP 1.5HP 1.5HP 2HP 3HP
Waveform Pure sine wave / same as input (bypass mode)
Nominal Output Voltage RMS 110V / 115V / 120VAC(±10% RMS)
Output Frequency 50Hz / 60Hz ±0.3Hz
Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%
Power Factor 1.0
Typical Transfer Time 10ms(max)
AC INPUT
Voltage 110/120VAC
Selectable Voltage Range 95~135VAC (For personal computers)
Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
BATTERY
Minimum Start Voltage (10V / 10.5V / 11V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Alarm (10V / 10.5V / 11V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Cut Off 10V / 10.5V / 11V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Voltage Alarm (13.8-14.5V)+1V for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (13.8-14.5V)+0.5V  for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
Idie Consumption-Search Mode Load ≤50±20W(120V)
CHARGER
Output Voltage Depends on battery type
Charge AC Input Breaker Rating 120V 1K/12A 1.5K/16A 2K/30A 3K/40A 4-6K/63A
Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A 20A 60A 30A 35A 40A
BYPASS & PROTECTION
Input Voltage Waveform Sine wave (grid or generator)
Nominal Input Frequency 50Hz or 60Hz
Overload Protection (SMPS Load) Circuit breaker
Output Short Circuit Protection Circuit breaker
Bypass Breaker Rating 120V 1K/16A 1.5K/20A 2K/30A 3K/40A 4-6K/63A
Max Bypass Current 30Amp
SOLAR CHARGER
Maximum PV Array Power 1250W 2500W 1250W 2500W 1250W 2500W 2500W 5000W 2500W 5000W 5000W 5000W
Maximum PV Charge Current 80A±4A
DC Voltage 12V / 24V auto work 24V / 48V auto work
MPPT Range @ Operating Voltage 16~95VDC @ 12V / 30~130VDC @ 24V 30~130VDC @ 24V  / 60~130VDC @48V 60~130VDC @48V
Maximum PV Array Open Circuit Voltage 145VDC
Standby Power Consumption <2W
MECHANICAL SPECIFICATIONS
Mounting Wall Mount
Dimensions (W*H*D) 423*247*197mm 597*247*197mm
Net Weight (Solar CHG)(kg) 17.2 17.7 21.8 20.7 25.2 25.5 38.9 36.5 42.5
Shipping Dimensions (W*H*D) 585*387*322mm 758*387*322mm
Shipping Weight (Solar CHG)(kg) 20 20.7 24.8 23.5 28.2 28.2 43 40.7 45
OTHER
Operation Temperature Range 0℃ to 40℃
Storage Temperature -15℃ to 60℃
Audible Noise 60dB MAX
Display LED+LCD
Standard Warranty 1 year