Please carefully confirm MUST company name and account before making payment to avoid any loss ! DETAILS x

PV1300 Series High Frequency Off Grid Solar Inverter (1-1.5KVA) PV1300 Series High Frequency Off Grid Solar Inverter (1-1.5KVA)

High Frequency Off Grid Solar Inverter

PV1300 Series (1-1.5KVA)

PV1300 is a cost effective , intelligent hybrid off grid solar inverter with power range 1000VA 1500VA. The LCD display offers friendly user-configurable button adjustment such as input voltage setting, AC/solar charger priority , mute setting. When battery voltage is low, it will automatically switch to AC grid to supply continuous power to the loads. It suitable for personal home use.

Features:
  • Simulated sine wave inverter
  • Built-in 50A PWM Solar Charge Controller
  • MFD (multi-function display)
  • 20A standard charging current from utility
  • AC/solar priority for output via MFD
  • 3 steps charging algorithm
  • Overload & short-circuit protection
  • Battery reverse polarity protection
  • Deep discharge protection
  • Auto restart while AC/solar is recovering
Where to Buy?

Overview

PRODUCT DETAILS


INVERTER SYSTEM CONNECTION

Specification

MODELPV13-1012PV13-1512PV13-1024PV13-1524
Nominal Battery System Voltage12VDC12VDC24VDC24VDC
INVERTER OUTPUT
Rated Power1000VA/600W1500VA/1000W1000VA/600W1500VA/1000W
WaveformSimulated Sine-wave
Nominal Output Voltage RMS230V
Output Voltage Regulation+10/-18%
Output Frequency50Hz/60Hz +/-1 Hz
Inverter Efficiency(Peak)>80%
Line Mode Efficiency>98%
Typical Transfer TimeTypical 6~8ms 10ms max
AC INPUT
Voltage230VAC
Selectable Voltage RangeNarrow (UPS Model)175~260VAC
Wide (INV Model)140~270VAC
Frequency Range40Hz-70Hz (Auto sensing)
BATTERY
Nominal Input Voltage12VDC24VDC
Minimum Start Voltage10.5VDC21.0VDC
Low Battery Alarm10.4VDC (min)20.8VDC (min)
Low Battery Cutoff10.0VDC20.0VDC 
High Voltage Cutoff15.5VDC (max)31.0VDC (max)
SOLAR CHARGER
Maximum PV Charge Current50A (max)
Maximum PV Array Power450W/750W900W/1500W
PWM Range @ Operating Voltage16~55VDC
Maximum PV Array Open Circuit Voltage55VDC
Maximum Efficiency>95%
Standby Power Consumption<2W
AC Charger Voltage14.4V(max)28.8V(max)
AC Charging Current10A 
BYPASS
Nominal Input Frequency40Hz – 70Hz
Overload Protection (SMPS Load)FUSE
Output Short Circuit ProtectionFUSE
Bypass Fuse Rating10A
Max Bypass Current10Amp
MECHANICAL SPECIFICATIONS
Machine Dimensions (W*H*D)231*290*92mm
Package Dimensions (W*H*D)595*375*315mm
Net Weight (kg)2.84
Gross Weight (kg)3.54.7
OTHER
Operation Temperature Range0°C to 50°C
Audible Noise50dB MAX
DisplayLED+LCD
Loading(20GP/40GP/40HQ)1700pcs / 4100pcs

We'd Love to Hear From You

*required
*required
*required
*required