Galaxy III Series Integrated Micro Data Center Galaxy III Series Integrated Micro Data Center Galaxy III Series Integrated Micro Data Center

Integrated Micro Data Center

GALAXY III SERIES (3-30KVA OPTIONAL)

Galaxy III Series Micro Data Center is a new-generation data center solution. It is integrated with PDU, UPS, monitoring , cooling and rack system in a comprehensive rack in order to save space. The IT cabinet can be flexibly extended on both sides of it. A single module supports a maximum of 9 cabinets, at most 27 kW IT load, and up to 10 kW/R power density. Cold and hot aisle containment to saving Energy and reduce noise.

Features:
  • IP5X Full-closed Cabinet
  • Internal available space is up to 31U
  • Monitoring all-in-one machine
  • Full-load Noise≤55dB
  • Modular design, can expand with the development of data center
Where to Buy?

Overview

↓↓↓Installation Portfolio------------

MUSTENERGY

General Scheme

Power Supply System 220V/380V,50/60Hz,L+N+PE/3Ph+N+PE
System Protection Level IP5X
Running Temperature -20℃~45℃(-40℃~45℃)
(Low temperature mode supports -40℃~45℃)
Number of Single Module Cabinet
inet
1-12
(Specifically according to customer configuration)
Numble of IT Cabinet 1~9
(Specifically according to customer configuration)
Maximum Power Consumption for IT Load 27kW
(Specifically according to customer configuration)
Power Density of Single Cabinet 1-10kW
Installations Concrete Floor, Overhead Floor
Load Bearing of IT Cabinet 2200kg
Size(Height×Width×Depth) Single Cabinet2000×600×1200
( Rack-mounted Air-conditioning)

Cooling System

Power Supply Mode 220Vac,50Hz,1Ph+N+PE
Cooling Capacity of 
Temperature Control System
4.2kW/8.1kW(Rack-mounted Air-conditioning)
Running Temperature -40℃~+45℃
Typical Configuration
of Temperature Control System
N,N+1
Cooling Mode Air Cooling
Installations of Temperature Control System Rack-mounted Installation
Air Volume (Single Unit) 800m3/h、1500m3/h
Air Supply Mode Air Supply in the Front, Air Return in the Back (Rack-mounted Air-conditioning)

Power Suply and Distribution System

Lightning Protection Level CLASSII/C,In 20kA,Imax 40kA,8/20us
Power Input Single or double route optional
UPS Rack-mounted UPS 3kVA、6kVA、10kVA、20kVA、30kVA
UPS Rack-mounted Modular UPS 20kVA、30kVA
Configuration of UPS N、N+1、2N
Range of UPS Input Voltage 3kVA:110~288Vac  
6kVA、10kVA:120~275Vac
20kVA、30kVA:208~478Vac
Factors of UPS Output Power 0.9
Standby Time of Battery 0~60min (Decided by Customer)
Layout of Battery Rack-mounted Installation, Placed on the Plate, Battery Elevator (Cabinet) Intallation
PDU One-way or Two-way

Monitoring System

Monitoring Host Standard Embedded Monitoring Software, host and display are intergrated to save space.
Functional Module Report Management, Photo Monitoring, Alarm Management, Centralized Management
Access Mode Local Access, Remote Web Access
Local Display HD Display of 10.4-Inch
Alarm Mode Local alarm, SMS Alarm (Optional)

Typical Configuration

TypeGlass door closed passage type
Product nameSingle cabinet 3kVASingle cabinet 6kVATwo combination cabinet 6kVATwo combination cabinet 10kVAThree combination cabinet 10kVA
Number of cabinet11223
Available space30U28U70U65U107U
UPS3kVA6kVA6kVA10kVA10kVA
Air-Conditioning4.2kW4.2kW4.2kW2*4.2kW2*4.2kW
PDU16Bits National standard 10A16Bits National standard 10A2*16Bits National standard 10A2*16Bits National standard 10A3*16Bits National standard 10A
Battery12V 9AH Battery pack is standby for 10 minutes12V 9AH Battery pack is standby for 10 minutes12V 9AH Battery pack is standby for 10 minutes12V 9AH Battery pack is standby for 5 minutes12V 9AH Battery pack is standby for 5 minutes
Size(H*W*D)mm600*1200*2000600*1200*20001200*1200*20001200*1200*20001800*1200*2000
Monitoring systemStandard configuration: Touch display, Temperature and humidity, Smoke sensor, Leakage, Magnetic sensor, UPS management, Air conditioning managemnet, Electrical measurement, Visiable two-color ambient lamp, Lighting system
Emergency modeYHA:Automatic door; YHB:Ventilating and Radiating module for emergency; YHC:Ventilator for emergency + Automatic door