Please carefully confirm MUST company name and account before making payment to avoid any loss ! DETAILS x

EP3300 TLV Series Low Frequnecy Pure Sine Wave Split Phase Inverter Charger (1-6KW)

Low Frequnecy Pure Sine Wave Split Phase Inverter Charger

EP3300 TLV Series Split Phase (1-6KW)

This split phase inverter EP3300 TLV series, capacity from 1KW-6KW, DC 12V/24V/48V, it’s applicable to 110VAC/120VAC markets demands, which matches AC 110VAC/120V single phase, or two phase 110VAC/120V 120V/240V; In LCD display, you can set output voltage, frequency, charging voltage, charging current to design best use based on different loads applications; meanwhile, you can also connect extra solar charger controller to build a solar home system, take use of sunshine freely and save electricity bills.

Features:
  • Pure sine wave output, split phase HOT1+ N + HOT2 available, 120VAC/220VAC
  • MFD (multi-function display) & Friendly user interface
  • 3 Steps optimizing charge for battery pack
  • Overload and short-circuit protection
  • Settable: charging/charging current, utility/Battery priority, utility input wide/narrow range
  • Inverter voltage can be set to 100V/110V/120V
  • Inverter frequency can be set to 50/60Hz

Two Colors Option:

Silver
Bule
Where to Buy?

Overview

Pure sine wave output

Two pure sine wave AC 110V/120V output(Split Phase)


Smart Battery Chargers – 3 setps optimizing battery charge

Boost CC Stage: If A/C input is applied, the charger will run at full current in CC mode until the charger reaches the boost voltage.

Boost CV Stage: the charger will keep the boost voltage in Boost CV mode until the charge current less 6A continue 1minute or keep the boost voltage time more than 2hours . Then drop the voltage down to the float voltage.

Float Stage: In float mode, the voltage will stay at the float voltage. If the A/C is reconnected , the charger will reset the cycle above.


Easy to read all working modes and parameters in LCD


Line Mode

Input power will provide energy to load directly. And it will charge the battery at the same time.If voltage of input power is outside of section, the machine will switch to battery mode.


Battery Mode

The unit will get energy from battery and provide to load.


Fault Mode

If any fault has happened, the machine will enter to the mode. And fault code is displayed on the LCD.


Smart setting to make inverter work more efficiency


PRODUCT DETAILS


INVERTER SYSTEM CONNECTION

EP3300 TLV, split phase inverter, it can support different loads with it’s inbuilt pure copper transformer, like laptop, TV, Air-conditioner, fridge etc… Normally this inverter work with battery as back up system to meet different power demands in daily life; it can also connect extra MPPT/PWM solar charge controller, then work as an solar inverter system, use sunshine energy to save electricity bills.


APPLICABLE PLACE


Model EP33-1012TLV EP33-1024TLV EP33-1512TLV EP33-1524TLV EP33-2012TLV EP33-2024TLV EP33-3024TLV EP33-3048TLV EP33-4024TLV EP33-4048TLV EP33-5048TLV EP33-6048TLV
Inverter Output
Rated power(W) 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW
Power Factor 1
Wave form Pure sine wave/ Same as input waveform (bypass mode)
Output voltage RMS 100V/110V/120VAC(200V/220V/240VAC)±10%
Output frequency 50HZ or 60HZ (±0.3HZ) (can be set)
Overload protection Breaker + software protection
Output short circuit Breaker + software protection
Inverter efficiency(peak) >80%
Overload 100%<Load<110% (alarm 5min then stop output and fault code 07); 110%<Load<125% (alarm 60s then stop output and fault code 07); Load>125% (alarm 10s then stop output and fault code 07)
Surge rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
Capable of starting electric motor 1P 1P 1.5P 1.5P 2P 3P
Battery
Battery voltage 12VDC/24VDC 24VDC/48VDC 48VDC
Minimum start voltage 11VDC/22VDC/44VDC
Low battery voltage cut off (low voltage fault code04)10/10.5/11V for 12V model(*2 for 24DVC / *4 for 48VDC)
Low battery voltage alarm Add 0.5V/battery: (low battery alarm one second one time) (10/10.5/11V) + 0.5Vdc for 12V model(*2 for 24DVC / *4 for 48VDC)
High battery voltage alarm Add +1V/battery: (high voltage one second one time/after 30s fault 03) (13.8-14.5V) + 1V for 12V model(*2 for 24DVC / *4 for 48VDC)
Save mode Load≤40W(110V)/80W(220V)
AC Input Mode
Input waveform Pure sine wave
Nominal input voltage 220Vac / 230Vac / 240Vac
Max input voltage 270Vac MAX
Input frequency 50HZ/60HZ (auto sensing)
Efficiency(AC mode) >95% (load, full battery)
Transfer time AC TO DC 15ms(max)
Transfer time DC TO AC 15ms(max)
Charge Mode
Boost Voltage 14.1V(Default) Range of adjustment 13.8-14.5V/*2 for 24VDC/*4 for 48VDC (Regulation step 0.1V)
Float Voltage 13.5V(default) Range of adjustment 13.5-13.7V/*2 for 24VDC/*4 for 48VDC (Regulation step 0.1V)
12V 30A 45A 60A
24V 20A 25A 30A 40A 60A
48V 20A 30A 35A 40A
Min charge current 10A. change by every 5A.
Dimensions
Dimensions (W*H*D) 277*196*466mm 277*186*621mm
Ship Dimensions (W*H*D) 376*306*592mm 376*296*747mm
Warranty One year(standard),2years optional(IP20)

*Products specifications are subject to change without further notice

We'd Love to Hear From You

*required
*required
*required
*required