Please carefully confirm MUST company name and account before making payment to avoid any loss ! DETAILS x

EP3300 TLV Series Low Frequency Pure Sine Wave Split Phase Inverter Charger (1-6KW) EP3300 TLV Series Low Frequency Pure Sine Wave Split Phase Inverter Charger (1-6KW)

Low Frequency Pure Sine Wave Split Phase Inverter Charger

EP3300 TLV Series Split Phase Inverter (1-6KW)

This split phase inverter EP3300 TLV series, capacity from 1KW-6KW, DC 12V/24V/48V, it’s applicable to 110VAC\120VAC markets demands, which matches AC 110VAC\120V single phase, or two phase 220V\240V; In LCD display, you can set output voltage, frequency, charging voltage, charging current to design best use based on different loads applications; meanwhile, you can also connect extra solar charge controller to build a solar home system, take use of sunshine freely and save electricity bills.

Features:
  • Pure sine wave output, split phase HOT1+ N + HOT2 available, 120VAC/220VAC
  • MFD (multi-function display) & Friendly user interface
  • 3 Steps optimizing charge for battery pack
  • Overload and short-circuit protection
  • Settable: charging/charging current, utility/Battery priority, utility input wide/narrow range
  • Inverter voltage can be set to 100V/110V/120V
  • Inverter frequency can be set to 50/60Hz
Where to Buy?

Overview

MODEL EP33- 1012 TLV EP33- 1024 TLV EP33- 1512 TLV EP33- 1524 TLV EP33- 2012 TLV EP33- 2024 TLV EP33- 3024 TLV EP33- 3048 TLV EP33- 4024 TLV EP33- 4048 TLV EP33- 5048 TLV EP33- 6048 TLV
Inverter Output
Rated power 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW
Surge rating 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA
Capable of starting electric motor 1P 1P 1.5P 1.5P 2P 3P
Power factor 1
Wave form Pure sine wave / Same as input wave form (bypass mode)
Output voltage RMS 100V / 110V / 120VAC (200V / 220V / 240VAC) ±10%
Output frequency 50Hz or 60Hz (±0.3Hz) (can be set)
Overload protection Breaker + software protection
Output short circuit Breaker + software protection
Inverter efficiency (peak) >80%
Overload 100% < Load < 110% (alarm 5min then stop output and fault code 07) 110% < Load < 125% (alarm 60s then stop output and fault code 07) Load > 125% (alarm 10s then stop output and fault code 07)
Battery
Battery voltage 12VDC / 24VDC 24VDC / 48VDC 48VDC
Minimum start voltage (10V / 10.5V / 11V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low battery voltage cut off 10V / 10.5V / 11V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low battery voltage alarm (10V / 10.5V / 11V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High battery voltage alarm (13.8-14.5V)+1V for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (13.8-14.5V)+0.5V  for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
Save mode Load ≤50±20W(120V)/100±20W(220V)
AC Input Mode
Input waveform Pure sine wave
Nominal input voltage 200Vac / 220Vac / 240Vac
Max input voltage 270Vac MAX
Input frequency 50Hz / 60Hz (auto sensing)
Efficiency (AC mode) >95% (load, full battery)
Transfer time AC to DC 15ms(max)
Transfer time DC to AC 15ms(max)
Charge Mode
Boost voltage 14.1V(Default) Range of adjustment 13.8-14.5V / *2 for 24VDC / *4 for 48VDC (Regulation step 0.1V)
Float voltage 13.5V(Default) Range of adjustment 13.5-13.7V / *2 for 24VDC / *4 for 48VDC (Regulation step 0.1V)
12V 30A 45A 60A / / / /
24V 20A 25A 30A 40A 60A / /
48V / / / 20A 30A 35A 40A
Min charge current 10A. Change by every 5A
Dimensions
Dimensions (W*H*D) (mm) 277*196*466mm 277*186*621mm
Ship Dimensions (W*H*D) (mm) 381*316*597mm 381*306*752mm
Warranty One year (standard), 2 years optional (IP20)

Software and Instruction Manual Downloads>>>


                   

We'd Love to Hear From You

    *required
    *required
    *required
    *required