EP3000 PRO Series Low Frequency Pure sine wave Inverter (8-12KW) EP3000 PRO Series Low Frequency Pure sine wave Inverter (8-12KW)

Low Frequency Pure Sine Wave Inverter

EP3000 PRO Series (8-12KW)

Low frequency pure sine wave combined inverter&A/C charger EP3000 PRO Series 8 -12kw; Quiet,high efficiency operation front panel LED+LCD indicators and adjustable switch selectors selectable settings for flooded lead acid,Gel,or absorbed glass mat(AGM) batteries. Mainly for home and office applicances such as TV, refrigerator, fans lights and computers etc.

Features:
  • Pure sine wave output
  • Max 140A automatic 3-stage battery charger
  • Charger current is Adjustable (0-100%)
  • Automatically send signal to start generator
  • Supporting USB communicaion and BTS & AGS port
  • Battery/AC priority
Where to Buy?

Overview

↓↓↓Installation Portfolio------------

MUSTENERGY
MODEL EP30-8KW PRO EP30-10KW PRO EP30-12KW PRO
Nominal Battery System Voltage 48VDC 48VDC 48VDC
INVERTER OUTPUT
Continuous output power 8.0KW 10.0KW 12.0KW
Surge rating 24000VA 30000VA 36000VA
Capable Of Starting Electric Motor 4HP 5HP 6HP
Output waveform Pure sine wave / same as input (bypass mode)
Inverter Efficiency(Peak) >88%
Line mode efficiency >95%
Power factor 1.0
Nominal output voltage RMS 220V / 230V / 240VAC ±10% (RMS)
Output frequency 50Hz
Short circuit protection Yes (1sec after fault)
Typical transfer time 10ms(max)
AC INPUT
Voltage 90-280VAC
Selectable Voltage Range 170-280VAC(For Personal Computers)
Frequency Range 50Hz / 60Hz
BATTERY
Minimum start voltage 40.0V±0.6 / 42.0V±0.6
Low battery alarm 42-50VDC
Low battery Cutoff 40.0V±0.6 / 42.0V±0.6
High voltage alarm 60VDC
High battery voltage recover 57VDC
Idle consumption-search mode <60W when power saver on
CHARGER
Output voltage Depends on battery type
Charger AC input breaker rating 80A
Max charge power rate 1/3 Rating power
Overcharge protection S.D. 62.8VDC
Maximum Charge Current 100A 120A 140A
BTS
Temperature rate @25°C 4mv charging voltage descent, per 1℃ rise
BYPASS & PROTECTION
Input voltage waveform Sine wave (grid or generator)
Nominal voltage 220V / 230V / 240VAC
Max input AC voltage 300VAC for 230VAC HV mode
Nominal input frequency 50Hz or 60Hz
Overload protection (SMPS load) Circuit breaker
Output short circuit protection Circuit breaker
Bypass breaker rating 63A
Max bypass current 63Amp
MECHANICAL SPECIFICATIONS
Mounting Wall mount
Inverter dimensions (W*H*D) (mm) 670*410*215
Inverter weight (solar chg) (kg) 67.5 74 74
Shipping dimensions (W*H*D) (mm) 802*533*429.5
Shipping weight (solar chg) (kg) 87 93.5 93.5
OTHER
Operation   Temperature  Range 0℃ to 40℃
Storage   Temperature -15℃ to 60℃
Audible   Noise 60bB MAX
Display LED+LCD
Loading(20GP/40GP/40HQ) 200pcs / 400pcs / 500pcs

We'd Love to Hear From You

    *required

    *required

    *required