Please carefully confirm MUST company name and account before making payment to avoid any loss ! DETAILS x

EP3000 LV Series Low Frequency Pure Sine Wave Inverter (1-4KW) EP3000 LV Series Low Frequency Pure Sine Wave Inverter (1-4KW)

Low Frequency Pure Sine Wave Inverter

EP3000 LV Series (1-4KW)

EP3000 LV series is very economical pure sine wave inverter, special in north & south america market, and AC charger from 35A to 70A .Solar /AC priority configurable . When solar priority , in case its charge current lower than inverter’s charger from AC , AC will supplement to charge the batteries ,to optimize charging. With low frequency transformer ,it enable the inverter to operate with all kinds of home appliances.

Features:
  • Nominal Output Voltage RMS: 100V/110V/120VAC (±10% RMS)
  • Rated power 1kw to 4kw
  • Pure sine wave output
  • 3 times surge power
  • Wide frequency 40Hz-80Hz
  • Overload and short circuit protection
  • Built-in pure copper UI transformer
  • Smart battery charger designed for optimized battery performance
  • Cold start function
  • Support RS232 monitoring function with free CD
  • Support BTS and AGS function
  • DIP Switch offer customized performance
  • Remote Control Panel (optional)
  • Compatible to generator
Where to Buy?

Overview

SINEWAVE
Pure Sine Wave

Pure sine wave output.

bao
Battery Protection

Overload & short circuit protection.

BATTERY
Smart Battery Chargers

Smart battery charger design for optimized battery performance.


LCD/LED Display Information

1. SwitchON(Power Saver): Power on with saver mode(power saver 25W)
INVERTER OFF: Power totally off(If there is AC power,inverter have charger function)
ON: Power on without saver mode

2. AC Charge
3. AC power
4. Inverter mode
5. Check inverter
6. Charge current adjustable:25%,50%,75%,100%.(Optional)


Figure 1 Back Panel Information

1. Battery input
2. RS232 communication port
3. Charger Input Protect
4. Inverter Output Protect
5. Output 10A MAX
6. AGS
7. BTS
8. DIP Switch (SW1-SW5)
9. Remote control


Inverter System Connection

EP3000 LV series is very economical pure sine wave inverter, special in north & south america market, and AC charger from 35A to 70A .Solar /AC priority configurable . When solar priority , in case its charge current lower than inverter’s charger from AC , AC will supplement to charge the batteries ,to optimize charging. With low frequency transformer ,it enable the inverter to operate with all kinds of home appliances.

Specification

MODELEP30-1012 LVEP30-1024 LVEP30-1512 LVEP30-1524 LVEP30-2012 LVEP30-2024 LVEP30-3012 LVEP30-3024 LVEP30-3048 LVEP30-4024 LVEP30-4048 LV
Nominal Battery System Voltage12VDC24VDC12VDC24VDC12VDC24VDC12VDC24VDC48VDC24VDC48VDC
INVERTER OUTPUT
Reted Power1.0KW1.5KW2KW3KW4KW
Surge Rating (20ms)3.0KW4.5KW6.0KW9.0KW12KW
Capable Of Starting Electric Motor1HP2HP
WaveformPure sine wave/ same as input (bypass mode)
Nominal Output Voltage RMS100V/110V/120VAC (±10% RMS)
Output Frequency50Hz/60Hz±0.3 Hz
Inverter Efficiency(Peak)>88%
Line Mode Efficiency>95%
Power Factor1.0
Typical Transfer Time10ms(max)
AC INPUT
Voltage120VAC
Selectable Voltage Range80~135VAC(For Personal Computers)
Frequency Range50Hz/60Hz (Auto sensing) 40~80Hz
BATTERY
Minimum Start Voltage10.0VDC /10.5VDC for12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Alarm10.5VDC±0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Cut off10.0VDC±0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Voltage Alarm16.0VDC±0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover15.5VDC±0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC)
Idle Consumption-Search Mode<25W when power saver on
CHARGER
Output VoltageDepends on battery type
Charger AC Input Breaker Rrating10A30A40A
Overcharge Protection S.D.15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
Maximum Charge Current35A20A45A25A65A35A75A45A30A65A35A
BYPASS&PROTECTION
Input Voltage WaveformSine wave (grid or generator)
Nominal Input Frequency50Hz or 60Hz
Overload Protection (SMPS Load)Circuit breaker
Output Short Circuit ProtectionCircuit breaker
Bypass Breaker Rating10A30A40A
Max Bypass Current30Amp40Amp
MECHANICAL SPECIFICATIONS
MountingWall Mount
Dimensions (W*H*D)426*206*178 mm601*206*178mm
Net Weight (Solar CHG) kg16.51721.1202624.524.838.235.8
Shipping Dimensions(W*H*D) 750*335*300mm
Shipping Weight (Solar CHG) kg19.32024.122.829.127.527.542.340
OTHER
Operation Temperature Range0°C to 40°C
Storage Temperature-15°C to 60°C
Audible Noise60dB MAX
DisplayLED+LCD
Standard Warranty1 year

Approximate Back-up Time Table

Power Rate(w)backup time(H) @1*100Ahbackup time(H) @2*100Ahbackup time(H) @4*100Ahbackup time(H) @4*200Ahbackup time(H) @8*200Ah
10000.48061.6023.503047.6896 
20000.21360.48061.6023.503047.6896
30000.10680.28480.85442.1364.8416
4000 0.21360.48061.6023.50304