Please carefully confirm MUST company name and account before making payment to avoid any loss ! DETAILS x

EP2000 Tower Series Low Frequency Pure Sine Wave Inverter (0.6-10KW) EP2000 Tower Series Low Frequency Pure Sine Wave Inverter (0.6-10KW)

Low Frequency Pure Sine Wave Power Inverter

EP2000 Tower Series (0.6-10KW)

Features:
  • Overload and short circuit protection;
  • Cold start function;
  • Wide input voltage range(145-280VAC);
  • Pure sine wave output;
  • LCD/LED option;
  • Built in AVR;
  • Max charge current 25A.
Where to Buy?

Overview

bao
Battery Protection

Overload and short circuit protection.

SINEWAVE
Pure Sine Wave

Pure sine wave output.

LEDLCD
LED/LCD

LCD/LED option.


ep2000-2

LCD/LED Display Information

1. Load indicator
2. 100%
3. 75%
4. 50%
5. 25%
6. Broken-down indicator
7. Inversion / Charge indicator
8. Line on
9. 100%
10. 75%
11. 50%
12. 25%
13. Battery capacity


LCD/LED Display Information

1. Output LED
2. Commercial Voltage LED
3. Load LED
4. Input LED
5. Output LED
6. Battery LED
7. Battery capacity LED
8. State LED(Normal LED/Alarm LED)

ep2000-1

ep2000-4

Figure 1 Back Panel Information

1. Fan
2. Battery input
3. Output socket
4. AC output connect load
5. AC Input


Inverter System Connection

This manual contains information regarding the installation, operation and use of the equipment.It is advised that this User’s Manual be consulted before installation of the equipment, which operation shall only be carried out by qualified personnel. Thereafter, it shall be kept and referred to whenever it is neccessary to carry out work on the equipment.

ep2000a

Specification

MODEL 600T 1000T 1500T 2000T 3000T 4000T 5000T 6000T 7000T 10000T
Default Battery System Voltage 12VDC/24VDC 24VDC 48VDC 96VDC
INVERTER OUTPUT
Reted Power 600W 1000W 1500W 2000W 3000W 4000W 5000W 6000W 7000W 10000W
Waveform Pure sine wave
Nominal Output Voltage RMS 100V/110V/120VAC 220V/230V/240VAC(±10% RMS) 220V/230V/240VAC(±10% RMS)
Output Frequency 50Hz/60Hz±0.3 Hz
Inverter Efficiency(Peak) >80%
Line Mode Efficiency >95%
Power Factor 1.0
Typical Transfer Time Typical 2~6ms ,10ms max
AC INPUT
Voltage 100V/110V/120VAC 220V/230V/240VAC 220V/230V/240VAC
Selectable Voltage Range 96~132VAC 145~275VAC(For Personal Computers) 145~275VAC(For Personal Computers)
Frequency Range 50Hz/60Hz (Auto sensing 44~68Hz)
BATTERY
Nominal Input Voltage 12VDC/24VDC 24VDC 48VDC 96VDC
Minimum Start Voltage 10.5VDC /21.0VDC/42VDC/84VDC
Low Battery Alarm 10.5±0.3V /21VDC±0.6V/42VDC±1.2V/84VDC±2.4V
Low Battery Cutoff 10.0±0.3V/20VDC±0.6V/40VDC±1.2V/80VDC±2.4V
High Voltage Alarm 15.5±0.3V/31VDC±0.6V/62VDC±1.2V/124VDC±2.4V
High Battery Voltage Recover 15.0±0.3V/30VDC±0.6V/60VDC±1.2V/120VDC±2.4V
CHARGER
Charger Voltage 14V±0.2V/28V±0.4V/56V±0.8V/112V±1.2V
Overcharge Protection S.D. 15.5VDC/31VDC/62VDC/124VDC
Maximum Charge Current 15A~25A
BYPASS & PROTECTION
Nominal Input Frequency 50Hz or 60Hz
Overload Protection (SMPS Load) IPS automatically shutdown if overload exceeds 120% ofnormal value for 30 seconds IPS automatically resume work if overload comes back to rated load
Output Short Circuit Protection FUSE Circuit breaker
Bypass Breaker Rating 10A 15A 30A 50A
Max Bypass Current 10A 15A 30A 50A
MECHANICAL SPECIFICATIONS
Dimensions (W*H*D) 140*182*380 255*385*470 260*750*570
Net Weight (kg) 11 12 24.2 27.4 29.5 33 35 41 47 53
Shipping Dimensions(W*H*D) 215*285*465 325*473*595 480*1030*720
Shipping Weight (kg) 12 13.2 26.9 30.1 33.2 35.7 49 55 61 67
OTHER
Operation Temperature Range 0°C to 40°C
Audible Noise 60dB MAX
Display LED or LCD Optional
Standard Warranty 1 year

Approximate Back-up Time Table

Power Rate(w) backup time(H) @1*100Ah backup time(H)@2*100Ah backup time(H)@4*100Ah backup time(H)@4*200Ah backup time(H)@8*200Ah
600 1.75 3.5 7 14  
1000 1 2.1 4.2 8.4  
2000   0.4806 1.602 3.50304 7.6896
3000   0.2848 0.8544 2.136 4.8146
4000     0.4806 1.602 3.50304
5000     0.34176 1.19616 2.73408
6000     0.2848 0.8544 2.136
7000         2.4
10000         1.7

We'd Love to Hear From You

*required
*required
*required
*required