Product Category
Power Inverter- EP1000 series 500VA-2KVA Inverter (LED/LCD)
- EP2000 series 300W-1500W Sinewave Inverter
- EP2000 series 5KW-10KW Sinewave Inverter (LCD)
- EP2000 series 1KW-4KW Sinewave Inverter (LCD)
- EP2000 series 12KW-16KW Sinewave Inverter (LCD)
- EP3000 Series 1K-4KW Sinewave Inverter/charger AC120V (LCD)
- EP3000 Series 1K-3KW Sinewave Inverter/charger AC230V (LCD)
- EP3000 Series 4KW-6KW Sinewave Inverter/charger AC230V (LCD)
- EP3000 Series 1KW-6KW SOLAR Inverter
- EP3000 Series 1KW-6KW power Inverter(LED)
- EP8000 series 500-5000VA Communications inverter
OffLine UPS- EA1000 series 500/650/800/1000VA UPS
- EA1150 Series 500/600/650VA UPS
Line Interactive UPS- EW2000 Series 500VA-1000VA UPS
- EW2110 Series 1200VA-1500VA LCD UPS
- EW2000 Series 1200VA-1500VA UPS
- EW2110 Series 500VA-1KVA LCD UPS
- EW2150 Series 500VA-1500VA Sine wave UPS
- EW2150 Series 1000VA-6000VA Sine wave UPS
On-Line UPS- EH5000 Series H1K/2K/3KVA UPS
- EH6000 Series H1K/2K/3KVA LCD UPS
- EH5000 Series H6KVA/10KVA UPS
- EH5110 Series R1kVA-6kVA RACK UPS
- EH5000 Series 3H10KS/15KS/20KS UPS
- EH9115 Series 1 Phase Low frequency UPS 2-15KVA
- EH9115 Series 3 Phase Low frequency UPS 10-80KVA
- EH9115 Series 3 Phase Low frequency UPS 100-160KVA
Voltage Regulators - EVS Series 500/800/1200VA AVR
- SVC Series 1KVA-20KVA voltage regulator
VRLA Battery- Gel Series VRLA Battery
- Electric Vehicle Series battery
- General Series VRLA Battery
- Deep Cycle Seris Battery
- GFM series VRLA Battery
- Solar Series VRLA Battery
- Front Terminal Serials Battery
Pure copper transformer inside and pure copper DC terninal port outside
Durable construction for long life under extreme environmental conditions
Applied in the field of industrial process controls, battery charging requirements, personal computers, telecommunications and others.
Built-in starting control circuits for two- and three-wire generator starting systems
Simplified controls with a snap-on cover that protects settings from being accidentally changed
Better thermal performance allows full output power to 50°C (122°F) without de-rating
High surge capacity starts more difficult loads and handles overload conditions reliably
Durable powder coated, corrosion resistant steel chassis
70-amp automatic three-stage battery charger (bulk, absorption, and float) and battery equalization with remote temperature sensor for increased performance
| MODEL | 230V Models | ||
| OUTPUT | |||
| Power Levels crated at nominal inputs | 1KW;2KW;3KW | ||
| Output Voltage | 220V/230V/240V Selectable | ||
| Voltage Waveform | Pure Sine wave | ||
| Crest Factor | 3:'1 | ||
| Output Frequency | Auto Select for 50/60Hz,47Hz ~55Hz for 50Hz nominal,56Hz ~ 65Hz for 60Hz nominal | ||
| (Synchronized to Mains) | |||
| efficienly(DC mode) | >80% | ||
| Surge Rating | 3000VA / 6000VA / 9000VA | ||
| Capable of motor | 1kw/2kw: 1HP 3KW:2HP | ||
|
Transfer time |
10ms typical | ||
| protection | Over load protection, battery over voltage & under voltage protection | ||
| Oover temperature protection | |||
| short circuit protection | |||
| INPUT | |||
| Nominal Voltage | 220V/230V/240V Selectable | ||
| Input Frequency | 40Hz ~ 80Hz, 50/60Hz auto-sensing | ||
| Efficiency (line mode) | >95% | ||
| Noise Filtering | Full time EMI/RFI filtering | ||
| Voltage Range | 155Vac-265Vac | ||
| Charge current | 65A max. | ||
| Inverter main features | huge charge current | ||
| pure copper transformer | |||
| pure sine wave | |||
| supports inductive loads | |||
| Surge Protection | 1KW-3KW:430 Joules | ||
| BATTERY | |||
| Battery type | Lead-Acid 50Ah~500Ah (Recommended) | Lead-Acid 50Ah~500Ah (Recommended) | |
| DC Voltage | 1KW:12Vdc | 2KW:12Vdc | |
| 2KW:24Vdc | 3KW:12Vdc | ||
| 3KW:24Vdc | 3KW: 48Vdc | ||
| Typical backup time | up to external battery | ||
| Charging method | battery charger (bulk, absorption, and float) | ||
| charge current is ajustable 25% 50% 75% 100% (optional) | |||
| Maximum charging current | 1000W 12V:35A | 2000W 12V:65A | |
| 2000W 24V:35A | 3000W 12V:65A | ||
| 3000W 24V:45A | 3000W 48V:25A | ||
| Average charging | Quick charging mode:15.7V-54V maximum. | ||
| voltage for each battery | Trickle charging mode:13.5V -52V | ||
| Protection | Over current protection | ||
| Over charging voltage protection | |||
| When temperature inside the unit is over 45°C ,charger will stop charging for 2 minutes followed by an 2 minutes charging. The cycle will be repeate | |||
| Monitoring | RS232 communication port | ||
| remote control cable 10 meters | |||
|
SOLAR CHARGER |
|||
| Rating voltage | 12V / 24V / 48V | ||
| DC input range | 12V model : 12 ~ 21Vdc;24V model : 24 ~ 42Vdc;48V model : 48 ~ 84Vdc | ||
| Charging method | Constant voltage with current limiting by PWM control | ||
| Charging voltage | 12V model:13.5Vdc;24V model: 27.0Vdc;48V model: 54.0Vdc | ||
| Power rating | 12V model : 1000W/2000W (13.5Vdc @ 37A) | ||
| 24V model : 1000W/2000W (27.0Vdc @ 37A) | |||
| 48V model : 3KW/4KW/5KW/6KW (54Vdc @ 18.5A) | |||
| Protection | DC input polarity protection, DC input short circuit protection. | ||
| (when battery is connected), DC output over current protection. | |||
| COMMUNICATIONS & MANAGEMENT | |||
| Control panel | LCD&LED indicators | ||
| Audible alarm | Alarm on battery:Low battery & Battery over voltage | ||
| Alarm on abnormal operation:Over load, Short-circuit, & Over heat | |||
| Green mode function | 1% to 14% of full load | ||
| (Auto-shut-off in blackout) | The default setting is OFF. | ||
| Cooling fan control | Auto on / off, controlled by temperature & operation mode | ||
|
ENVORMENT AND SAFETY |
|||
| Operating Temperature | Up to 1500 meters:0°C to 40°C (32°Fto 104°F) | ||
| Transit/storage Temp. | -15°C to 55(5°F to 131°F) | ||
| Relative Humidity | 5 - 95% non condensing | ||
| Operating Altitude | 0 ~ 3000 meters | ||
| Quality control system | ISO 9001 | ||
| PHYSICAL | |||
| Appearance | Size(mm)LxWxH | 570*315*300mm | |
| Weight(Kg) | 1000W/19kg ;2000W/24kg ;3000W/28kg | ||
this inverter can connect different kinds of loads,such as inductive loads and so on.Besides this point,can be used in extreme environments.