Product Category
Power Inverter- EP1000 series 500VA-2KVA Inverter (LED/LCD)
- EP2000 series 300W-1500W Sinewave Inverter
- EP2000 series 5KW-10KW Sinewave Inverter (LCD)
- EP2000 series 1KW-4KW Sinewave Inverter (LCD)
- EP2000 series 12KW-16KW Sinewave Inverter (LCD)
- EP3000 Series 1K-4KW Sinewave Inverter/charger AC120V (LCD)
- EP3000 Series 1K-3KW Sinewave Inverter/charger AC230V (LCD)
- EP3000 Series 4KW-6KW Sinewave Inverter/charger AC230V (LCD)
- EP3000 Series 1KW-6KW SOLAR Inverter
- EP3000 Series 1KW-6KW power Inverter(LED)
- EP8000 series 500-5000VA Communications inverter
OffLine UPS- EA1000 series 500/650/800/1000VA UPS
- EA1150 Series 500/600/650VA UPS
Line Interactive UPS- EW2000 Series 500VA-1000VA UPS
- EW2110 Series 1200VA-1500VA LCD UPS
- EW2000 Series 1200VA-1500VA UPS
- EW2110 Series 500VA-1KVA LCD UPS
- EW2150 Series 500VA-1500VA Sine wave UPS
- EW2150 Series 1000VA-6000VA Sine wave UPS
On-Line UPS- EH5000 Series H1K/2K/3KVA UPS
- EH6000 Series H1K/2K/3KVA LCD UPS
- EH5000 Series H6KVA/10KVA UPS
- EH5110 Series R1kVA-6kVA RACK UPS
- EH5000 Series 3H10KS/15KS/20KS UPS
- EH9115 Series 1 Phase Low frequency UPS 2-15KVA
- EH9115 Series 3 Phase Low frequency UPS 10-80KVA
- EH9115 Series 3 Phase Low frequency UPS 100-160KVA
Voltage Regulators - EVS Series 500/800/1200VA AVR
- SVC Series 1KVA-20KVA voltage regulator
VRLA Battery- Gel Series VRLA Battery
- Electric Vehicle Series battery
- General Series VRLA Battery
- Deep Cycle Seris Battery
- GFM series VRLA Battery
- Solar Series VRLA Battery
- Front Terminal Serials Battery
Applied in the field of industrial process controls, battery charging requirements, personal computers, telecommunications, graphics displays, plating and gold recovery industries and wherever required in the commercial, telecoms, mining or industrial markets. Commercial Solar, Recreational Vehicles, Mobile Office, Industrial Wind, Boats, Truck, & RV Residential Solar, Emergency Vehicles, Residential Wind, Fleet & Utility Vehicles, Camping & Outdoors, Renewable Newsletter.
Durable construction for long life under extreme environmental conditions
Low idle current (less than 1 watt) conserves energy when no loads are present
Soft start capability for starting heavy loads
Simplified controls with a snap-on cover that protects settings from being accidentally changed
Better thermal performance allows full output power to 50°C (122°F) without de-rating
High surge capacity starts more difficult loads and handles overload conditions reliably
Durable powder coated, corrosion resistant steel chassis
70-amp automatic three-stage battery charger (bulk, absorption, and float) and battery equalization with remote temperature sensor for increased performance
Pure copper transformer inside and pure copper DC terninal port outsideDurable construction for long life under extreme environmental conditions
| MODEL | 100/110/120V Models | ||
| OUTPUT | |||
| Power Levels crated at nominal inputs | 1KW;2KW;3KW;4KW | ||
| Output Voltage | 100V/110V/120VSelectable | ||
| Voltage Waveform | Pure Sine wave | ||
| Crest Factor | 3:1 | ||
| Output Frequency | Auto Select for 50/60Hz,47Hz ~55Hz for 50Hz nominal,56Hz ~ 65Hz for 60Hz nominal | ||
| Regulation (Nominal) | ±20% typical of nominal voltage | ||
| Regulation(Battery mode) | ±3% of selected output voltage (adjustable with the remote set-up software) | ||
| Transfer time (DC to AC) | 10 ms | ||
| Over current protection | Over load alarm level 100% ~ 120% Over load shutdown level 120% ~ 190% (Adjustable by using the remote set-up software) |
||
| INPUT | |||
| Nominal Voltage | 100V/110V/120V Selectable | ||
| Input Frequency | 40-80Hz, 50/60Hz auto-sensing | ||
| Efficiency (Normal mode) | 95% | ||
| Noise Filtering | Full time EMI/RFI filtering | ||
| Over current protection | Re-settable over current protector:1KW~4KW | ||
| Voltage Range | 100-127VAC | ||
| Features | huge charge current, short time charging | ||
| Other features | charge current adjustable:25% 50% 75% 100% | ||
| BATTERY | |||
| Battery type | Lead-Acid 50Ah~500Ah (Recommended) | ||
| DC Voltage | 1KW: 12Vdc 2KW: 12Vdc/24Vdc 3KW/4KW:24Vdc/48Vdc |
||
| Typical backup time | up to external battery | ||
| Charging method | battery charger (bulk, absorption, float) | ||
| Maximum charging current | 1000W 12V: 35A,2000W 12V:65A 2000W 24V: 35A,3000W 24V:45A 3000W 48V: 25A,4000W 48V: 35A |
||
| Average charging | Quick charging mode:15.7V-54V maximum. | ||
| voltage for each battery | Trickle charging mode:13.5V -52V | ||
|
Protection |
1.battery over voltage & under voltage protection |
||
| Monitoring | RS232 communication port | ||
| SOLAR CHARGER | |||
| Rating voltage | 12V / 24V / 48V | ||
| DC input range | 12V model : 12 ~ 21Vdc;24V model : 24 ~ 42Vdc;48V model : 48 ~ 84Vdc | ||
| Charging method | Constant voltage with current limiting by PWM control | ||
| Charging voltage | 12V model:13.5Vdc;24V model: 27.0Vdc;48V model: 54.0Vdc | ||
| Power rating | 12V model : 1000W/2000W (13.5Vdc @ 37A) | ||
| 24V model : 1000W/2000W (27.0Vdc @ 37A) | |||
| 48V model : 3KW/4KW (54Vdc @ 18.5A) | |||
| Protection | DC input polarity protection, DC input short circuit protection( when battery is connected), DC output over current protection | ||
| COMMUNICATIONS & MANAGEMENT | |||
| Standard Interface port | RS232 . | ||
| Optional Interface part | remote control | ||
| Control panel | LCD | ||
| Audible alarm | Alarm on battery:Low battery & Battery over voltage Alarm on abnormal operation:Over load, Short-circuit, & Over heat |
||
| Green mode function | 1% to 14% of full load | ||
| (Auto-shut-off in blackout) | The default setting is OFF. | ||
| Cooling fan control | Auto on / off, controlled by temperature & operation mode | ||
| ENVORMENT AND SAFETY | |||
| Operating Temperature | Up to 1500 meters:0°C to 40°C (32°Fto 104°F) | ||
| Transit/storage Temp. | -15°C to 55(5°F to 131°F) | ||
| Relative Humidity | 5 - 95% non condensing | ||
| Operating Altitude | 0 ~ 3000 meters | ||
| Quality control system | ISO 9001 | ||
| PHYSICAL | |||
| Appearance | carton(mm)LxWxH | 580*315*300 | |
| G.W(Kg) | 1000W/18.2kg ;2000W/24.5kg ;3000W/28kg | ||
| carton(mm)LxWxH | 755*319*288 | ||
| G.W(Kg) | 4000W/38kg | ||
It converts DC power into AC power. EP series will automatically transfer to inverter and provide power when AC supply is interrupted unexpectedly. Once set up, all functions of the inverter/charger are fully automatic.






