Product Category
Power Inverter- EP1000 series 500VA-2KVA Inverter (LED/LCD)
- EP2000 series 300W-1500W Sinewave Inverter
- EP2000 series 5KW-10KW Sinewave Inverter (LCD)
- EP2000 series 1KW-4KW Sinewave Inverter (LCD)
- EP2000 series 12KW-16KW Sinewave Inverter (LCD)
- EP3000 Series 1K-4KW Sinewave Inverter/charger AC120V (LCD)
- EP3000 Series 1K-3KW Sinewave Inverter/charger AC230V (LCD)
- EP3000 Series 4KW-6KW Sinewave Inverter/charger AC230V (LCD)
- EP3000 Series 1KW-6KW SOLAR Inverter
- EP3000 Series 1KW-6KW power Inverter(LED)
- EP8000 series 500-5000VA Communications inverter
OffLine UPS- EA1000 series 500/650/800/1000VA UPS
- EA1150 Series 500/600/650VA UPS
Line Interactive UPS- EW2000 Series 500VA-1000VA UPS
- EW2110 Series 1200VA-1500VA LCD UPS
- EW2000 Series 1200VA-1500VA UPS
- EW2110 Series 500VA-1KVA LCD UPS
- EW2150 Series 500VA-1500VA Sine wave UPS
- EW2150 Series 1000VA-6000VA Sine wave UPS
On-Line UPS- EH5000 Series H1K/2K/3KVA UPS
- EH6000 Series H1K/2K/3KVA LCD UPS
- EH5000 Series H6KVA/10KVA UPS
- EH5110 Series R1kVA-6kVA RACK UPS
- EH5000 Series 3H10KS/15KS/20KS UPS
- EH9115 Series 1 Phase Low frequency UPS 2-15KVA
- EH9115 Series 3 Phase Low frequency UPS 10-80KVA
- EH9115 Series 3 Phase Low frequency UPS 100-160KVA
Voltage Regulators - EVS Series 500/800/1200VA AVR
- SVC Series 1KVA-20KVA voltage regulator
VRLA Battery- Gel Series VRLA Battery
- Electric Vehicle Series battery
- General Series VRLA Battery
- Deep Cycle Seris Battery
- GFM series VRLA Battery
- Solar Series VRLA Battery
- Front Terminal Serials Battery
Applied in the field of industrial process controls, battery charging requirements, personal computers, telecommunications, graphics displays, plating and gold recovery industries and wherever required in the commercial, telecoms, mining or industrial markets. Commercial Solar, Recreational Vehicles, Mobile Office, Industrial Wind, Boats, Truck, & RV Residential Solar, Emergency Vehicles, Residential Wind, Fleet & Utility Vehicles, Camping & Outdoors, Renewable Newsletter.
Durable construction for long life under extreme environmental conditions
Low idle current (less than 1 watt) conserves energy when no loads are present
Soft start capability for starting heavy loads
Simplified controls with a snap-on cover that protects settings from being accidentally changed
Better thermal performance allows full output power to 50°C (122°F) without de-rating
High surge capacity starts more difficult loads and handles overload conditions reliably
Durable powder coated, corrosion resistant steel chassis
70-amp automatic three-stage battery charger (bulk, absorption, and float) and battery equalization with remote temperature sensor for increased performance
Pure copper transformer inside and pure copper DC terninal port outside.
| MODEL (EP3000) |
EP Model | |||||||
| 1012E | 1024E | 2012E | 2024E | 3024E | 4048E | 5048E | 6048E | |
| Line Mode Specifications: | ||||||||
| Input Voltage Waveform | Sinusoidal (utility or generator) | |||||||
| Nominal Input Voltage | 230Vac( selectable) | |||||||
| Low Line Disconnect | 155Vac±4% | |||||||
| Low Line Re-connect | 164Vac ±4% | |||||||
| High Line Disconnect | 272Vac±4% | |||||||
| High Line Re-connect | 265Vac±4% | |||||||
| Max AC Input Voltage | 270Vrms | |||||||
| Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | |||||||
| Low Line Frequency Re-connect | 58+0.3Hz for 60Hz;48+0.3Hz for 50Hz; | |||||||
| Low Line Frequency Disconnect | 57+0.3Hz for 60Hz;47+0.3Hz for 50Hz; | |||||||
| High Line Frequency Re-connect | 64+0.3Hz for 60Hz;54+0.3Hz for 50Hz; | |||||||
| High Line Frequency Disconnect | 65+0.3Hz for 60Hz;55+0.3Hz for 50Hz; |
|||||||
| Output Voltage Waveform | As same as Input Waveform | |||||||
| Over-Load Protection(SMPSload) | Circuit breaker | |||||||
| Output Short Circuit Protection | Circuit breaker | |||||||
| Efficiency (Line Mode) | >95% | |||||||
| Transfer Switch Rating | 30A | |||||||
| Transfer Time (Ac to Dc) | 10ms (typical) | |||||||
| Transfer Time (Dc to Ac) | 10ms (typical) | |||||||
| Charge current | current is adjustable 25% 50% 75% 100% | |||||||
| Max Bypass Overload Current | 1kw/2k/3kw: 30A 4kw/5kw/6kw: 40A | |||||||
| Invert Mode Specifications: | ||||||||
| Output Voltage Waveform | pure sine wave | |||||||
| Rated Output Power (VA) | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | ||
| Rated Output Power (W) | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | ||
| Power Factor | 1.0 | |||||||
| Nominal Output Voltage (V) | 230Vac | |||||||
| Nominal Output Frequency (Hz) | 50Hz ± 0.3Hz | |||||||
| Auto tracking Main Frequency(Hz) | Yes (Following Main first connection)50Hz @48-54Hz ;60Hz @58-64Hz | |||||||
| Output Voltage Regulation | ±10% rms | |||||||
| Efficiency (battery mode) | >80% | |||||||
Over-Load Protection (SMPS load) |
(110%<load<125%) ±10%: Fault (shutdown output) after 15 minutes;(125%<load<150%) ±10%: Fault (shutdown output) after 60s;Load>150% ±10%: Fault (shutdown output) after 20s; | |||||||
| Surge rating | 3000VA | 6000VA | 9000VA | 12000VA | 15000 VA | 18000VA | ||
| Capable of starting electric motor | 1 HP | 1 HP | 2 HP | 3 HP | ||||
| Output Short Circuit Protection | Current limit (Fault after 10s) | |||||||
| Bypass Breaker Size | 10A | 30A | 30A | 30A | 30A | |||
| Nominal DC Input Voltage | 12V | 24V | 12V | 24V | 24V | 48V | 48V | |
| Min DC start voltage | 11V/22V/43V | |||||||
| Low Battery Alarm | 10.5Vdc ± 0.3Vdc for 12V battery;21.0Vdc ± 0.6Vdc for 24V battery;42.0Vdc ± 0.6Vdc for 48V battery | |||||||
| Low DC input Shut-down | 10.0Vdc ± 0.3Vdc for 12V battery;20.0vdc± 0.6Vdc for 24V battery;40.0Vdc± 0.6Vdc for 48V battery | |||||||
| High DC input Alarm & Fault | 16Vdc ± 0.3Vdc for 12V battery;32Vdc ± 0.6Vdc for 24V battery; 64Vdc ± 0.6Vdc for 48V battery | |||||||
| High DC input Recovery | 15.5Vdc ± 0.3Vdc for 12V battery;31.0Vdc ± 0.6Vdc for 24V battery; 62.0Vdc ± 0.6Vdc for 48V battery | |||||||
| Power saver | Load ≤25W | |||||||
| Charge Mode Specifications: | ||||||||
| Nominal Input Voltage | 230Vac | |||||||
| Input Voltage Range | 155-265Vac | |||||||
| Nominal Output Voltage | same as input voltage | |||||||
| Nominal Charge Current | 35A | 35A | 70A | 35A | 45A | 35A | 40A | 50A |
| Charge Current Regulation | ± 5Adc | |||||||
| Battery initial voltage | 0 –15.7 Vdc (can operate with 0V battery) | |||||||
| Charger Short Circuit Protection | Circuit breaker | |||||||
| Over Charge Protection | Bat. V ≥ 15.7Vdc/31.4Vdc,beeps 0.5s every 1s & fault after 60s | |||||||
| General Specifications | ||||||||
| Safety Certification | CE/SONCAP | |||||||
| Safety Certification | FCC | |||||||
| Operating Temperature Range | 0°C to 40°C | |||||||
| Storage temperature | 15°C below zero to 60°C | |||||||
| Operation humidity | 5% to 95% | |||||||
| Audible Noise | 60dB max | |||||||
| Cooling | Forced air, variable speed fan | |||||||
| Size |
1012E/1024E/2012E/2024E/2048E/3012E/3024E/3048E:580X315X300MM |
|||||||
It converts DC power into AC power. EP series will automatically transfer to inverter and provide power when AC supply is interrupted unexpectedly. Once set up, all functions of the inverter/charger are fully automatic.